ISUZU NPR 132hp LHD DR Room Mobile Clinic Truck -
A full clinic that drivesto your patients.
01
Product overview
On an ISUZU KV600 4×2 cab-chassis sits a 4.4-metre walk-in clinic cabin, insulated to three functional zones: a lead-shielded DR (digital radiography) bay, an ECG station and a laboratory / phlebotomy counter. The whole envelope is welded steel plate — waterproof, thermally and acoustically insulated — lined inside with flame-retardant panels and finished to medical-grade standards.
Everything the team needs for a full outreach day travels with it: a 10 kW generator on a hydraulic lift cradle, a 200 Ah battery bank with charger/inverter, a 220 V dual-power transfer switch, an external power socket with a 30 m cable reel, climate control ducted to the medical area, and task, ambience and emergency lighting throughout.
It is still, underneath, a maintenance-friendly 8-tonne truck: 132 hp turbo-diesel, six-speed gearbox, air brakes with ABS, a 3.8 m wheelbase and a cabin anyone can board with a single hidden step ladder — no fixed clinic infrastructure required at the site.
02
Product applications
One platform, many programs — from a province-wide physical examination to an occupational-health round at a plant gate.
|

Rural & outreach primary care
Consultation, triage and on-the-spot diagnostics for barangays, villages and nomadic communities beyond clinic range.
|

TB & chest X-ray campaigns
Certified-grade DR bay supports mass screening drives with instant images for reading and referral.
|

Cardiac & NCD screening
ECG station plus height/weight capture for hypertension, diabetes and cardiovascular check-ups.
|

Lab & phlebotomy days
Sample draw, registration and prep counter with storage cabinets — partner lab courier takes it from there.
|
|

Occupational health checks
Pre-employment and annual medical exams delivered to factory gates, mines and plantation camps.
|

Epidemic & emergency response
Self-powered assessment and imaging post for outbreaks, disasters and displaced-population sites.
|

Maternal & child programs
Prenatal visits, child health days and immunisation support with cold-ready counter storage.
|

Private mobile clinics
Insurers, chains and NGOs brand the cabin as their own — see the delivered program unit in the photos.
|

03
Technical Specifications
| Chassis |
ISUZU KV600, single-row cab |
| Drive / layout |
4×2 · left-hand drive |
| Overall size |
≈ 6,900 × 2,450 × 2,900 mm |
| GVW / kerb mass |
8,000 / ≈ 4,480 kg |
| Clinic cabin |
4,400 × 2,550 mm walk-in van body |
| Zones |
DR bay · ECG · lab & phlebotomy |
| Engine |
4KH1CN6 · 2,999 cc · 132 hp @ 2,900 rpm |
| Onboard power |
10 kW genset + 200 Ah + shore inlet |
| Entry |
Right-side sliding door, hidden step ladder |
04
Why buyers choose this build
A lead room, not a curtain
The DR bay is lined on all six surfaces with 3 mm lead plate behind the wall panels, sealed by a 900 × 1,800 mm lead sliding door and watched through 15 mm lead glass — so exposures happen with an operator in the next zone, not in the parking lot.
- 3 mm lead sheet · walls, ceiling, floor
- Lead sliding door 900 × 1,800 mm
- Lead-glass window 590 × 590 × 15 mm
POWER
A clinic day without the grid
The 10 kW generator lowers out of its skirt bay on a hydraulic lift and runs the whole cabin; a 200 Ah battery bank with charger/inverter covers changeovers, and the dual-power converter accepts any industrial shore socket via the 30 m reel.
- 10 kW genset, hydraulic cradle
- 200 Ah battery + inverter/charger
- 220 V auto dual-source transfer
WORKFLOW
Three zones in 11 m²
DR bay, ECG station and lab / phlebotomy counter are separated by a sliding door and a privacy curtain, with worktops, drawered cabinets and a swivel operator chair — a screening queue flows one way, front to back.
- DR · ECG · lab-phlebotomy
- Chemical-board counters, storage below
- Named zones on the build sheet
BUILD
A box welded like a hull
Watertight-welded steel skeleton on a proper subframe (160 × 80 mm longitudinal beams), flame-retardant insulation foam-filled in the wall cavity, anti-rust-treated steels and stainless exterior fasteners, medical floor sheet over bamboo plywood.
- Heat & sound insulated panels
- Anti-rust pre- and post-weld treatment
- Flame-retardant interior laminates
ACCESS
Patients board it like a bus
Lowered side skirts keep the waist line low, a hidden ladder deploys under the entrance, and the right-side door takes a wheelchair-adjacent flow. Lift-up RV windows with screens and blinds bring daylight and cross-ventilation to the counters.
- Hidden boarding ladder
- Left / right down-sized skirts
- RV windows ×2: screen + sunshade
MOBILITY
Still a serviceable Isuzu
Under the clinic is an ordinary, fixable truck: 4KH1CN6 3.0 L turbo-diesel (132 hp / 290 N·m), 6-speed box, air brakes with ABS, hydraulic steering — parts and training exist in almost every market on earth.
- 7.50R16 tyres (6 + 1 spare)
- Air brake + ABS, spring brake
- 105 km/h cruise capability
05
Product details
Patient entry & counter line
Boarding is a level step, not a jump: a retractable ladder hides under the entrance skirt, the lowered waist line and right-side sliding door keep the queue moving, and two RV lift-up windows with screens and blinds bring daylight to the lab / phlebotomy counter.
Right-side sliding doorHidden boarding ladderRV windows ×2Lowered side skirts

ECG bench & work counter
Chemical-board worktops with lockable drawers run along the cabin wall: ECG recording, triage notes and sample logging happen here, opposite the fused distribution panel with meters and breakers. A swivel medical operator chair is standard.
Physical/chemical countertopMedical swivel chairDistribution cabinetPrivacy curtain

X-ray / DR bay
A hard-walled radiography room at the rear of the cabin: 3 mm lead sheet on all six surfaces, a 900 × 1,800 mm lead sliding door and a 590 × 590 mm lead-glass viewing window — so one operator supervises the exposure from the next zone.
DR wall-stand column6-side lead liningLead sliding doorLead glass 15 mm

06
Supported customization
Tick what applies to your tender or campaign — we return a drawing and a firm build sheet. Nothing starts cutting steel before you approve it.
07
Q&A
Is the X-ray room actually radiation safey? --------------------The bay is lined on all six surfaces with lead plate in the wall panels, closed by a lead sliding door (900 × 1,800 mm) and a 15 mm lead-glass viewing window. Shielding thickness can be recalculated and re-built to the limits set by your national radiological regulator before production starts.
Can I run a whole clinic day with no site power?---------------------------Yes. The 10 kW generator lowers out of its skirt bay on a hydraulic lift and feeds DR, ECG, A/C, lighting and counters; a 200 Ah battery bank with inverter/charger covers start-up and changeovers. If the site does have supply, plug into the industrial waterproof inlet — the dual-power converter switches sources for you.
What lience does the driver need, and can we drive it daily?---------------------------It is an 8-tonne GVW rigid truck with air brakes, ABS and a 6-speed gearbox — in most countries that means a standard medium/heavy truck licence, not a bus permit. The 132 hp Isuzu powertrain and 105 km/h top speed are built for road circuits between sites, not one-off deployments.
Can you fit our own DR/ECG/LAB equipment instead of yours?---------------------------Send us the models. We resize counters, brackets, circuits and shielding around your kit and return a drawing — most buyers swap in regulators-approved gear and reuse everything else unchanged.
What's the temperature inside?---------------------------The cabin walls are foam-filled composite panels in a welded waterproof shell — a thermos with doors. A 1.5 HP air conditioner is ducted specifically into the medical area so imaging electronics and samples stay within working range. Arctic insulation, heating and dust-sealed packages are optional.